










Touchscreens  | 
size  | 
15.6  | 
(body) temperature  | 
Displaying the exact number of digits  | 
0.1 °C  | 
Body temperature measurement mode  | 
32.0 to 42.5°C  | 
|
Object temperature measurement mode  | 
0 to 100°C  | 
|
precision  | 
≤±0.3°C  | 
|
power wastage  | 
≤120mw  | 
|
measuring distance  | 
5 to 8 cm  | 
|
automatic shutdown  | 
About 15 seconds.  | 
|
12-lead ECG  | 
Collection method  | 
12-lead synchronized ECG Wilson  | 
Power input  | 
d.c5.0V (powered by computer USB port)  | 
|
Sampling frequency  | 
500Hz  | 
|
Calibration voltage  | 
Calibration voltage:1 mV+5%.  | 
|
Gain Settings and Accuracy  | 
5 mm/mV (x0.5), 10 mm/mV (x1), 20 mm/mV (x2 ) shall be provided  | 
|
Input impedance  | 
≥5.0Ω  | 
|
Low Frequency Characteristics  | 
Time constant not less than 3.2 s  | 
|
oximetry  | 
sensors  | 
Dual Wavelength Light Emitting Diodes  | 
wave length  | 
Red light:663nm  | 
|
Infrared light:890nm  | 
||
Measurement Range  | 
35% to 100%;  | 
|
Maximum output power  | 
≤2mW  | 
|
measurement error  | 
The measurement error is ±2% in the range of 70% to 100%.  | 
|
Pulse rate measurement error  | 
30 to 250bpm The monitoring error is ±2bpm or ±%2, whichever is greatest.  | 
|
sphygmometer  | 
Display method  | 
Large LCD Digital  | 
Measurement method  | 
signal wave method  | 
|
Measurement Range  | 
Blood pressure:30~280mmHg  | 
|
Pulse rate:40 to 195 beats/min  | 
||
precision  | 
Pressure ±3mmHg  | 
|
Pulse rate number ±5%  | 
||
Pressurization / Pressure Relief  | 
Pressurization/decompression using a microelectronic air pump control system  | 
|
Storage function  | 
100 sets of measured values with date/time (no loss of memory)  | 
|
Suitable for arm circumference  | 
22cm to 32cm  | 
|
power supply  | 
DC 6V  | 
|
Use of temperature and humidity  | 
+5°C - +40°C RH ≤ 80% (measurement outside the range, measurement results have deviations)  | 
|
Preservation of temperature and humidity  | 
-20℃-+55℃ RH≤93% (measurement outside the range, measurement results have deviations)  | 
|
Operating atmospheric pressure  | 
525-795 mmHg  | 
|
Transport and storage atmospheric pressure  | 
375-795 mmHg  | 
|
A4 Printer Hewlett-Packard ( HP108A )  | 
resolution (of a photo)  | 
B&W (best mode): up to 1,200x1,200dpi; B&W (normal mode): up to 600x600dpi  | 
Printer Language  | 
GDI (host-based language)  | 
|
Print speed  | 
B&W (normal mode, A4): up to 20 pages/min; B&W (long-edge feed, A5): up to 30 pages/min  | 
|
Print load  | 
Up to 10,000 pages  | 
|
First Print Time  | 
B&W (A4, ready mode): only 8.3 seconds; B&W (A4, sleep mode): as fast as 18 seconds  | 
|
weight  | 
4.18 kg  | 
|
interface  | 
High-speed USB 2.0 port  | 
|
System Parameters  | 
Windows:7(32/64 bit), 2008 Server R2,8(32/64 bit),8.1(32/64 bit),10(32/64 bit),2012 Server,2016 Server  | 
|
size  | 
331*215*178 mm  | 
|
RAM  | 
64 MB  | 
|
power supply  | 
Power supply type: built-in power supply; power requirements: 110 volts input voltage: 110 to 127 volts AC, 50/60 Hz; 220 volts input voltage: 220 to 240 volts AC, 50/60 Hz  | 
|
Blood sugar, uric acid, total cholesterol  | 
autopsy  | 
Fingertip microvascular whole blood  | 
Detection time  | 
Blood sugar:in 10 seconds Uric acid:in 15 seconds Total cholesterol:in 26 seconds  | 
|
Scope of testing  | 
Blood glucose:20-600mg/dL (1.1-33.3mmol/L) Uric acid:3-20mg/dL (0.18-1.19mmol/L) Total cholesterol:100-400mg/dL (2.59-10.35mmol/L)  | 
|
volume of the body to be examined  | 
Blood glucose 0.9uL, total cholesterol 10uL, uric acid 1uL  | 
|
Storage temperature  | 
10°C - 30°C  | 
|
Operating temperature  | 
10°C - 40°C  | 
|
relative humidity  | 
<95%  | 
|
Memory capacity  | 
Blood glucose 360 group, total cholesterol 50 group, uric acid 50 group  | 
|
Battery life  | 
Approx. 1000 measurements  | 
|
Data output interface  | 
LAN interface  | 
|
Supply voltage  | 
220 AC (50Hz/60Hz)  | 
|
rating  | 
(100W) Max.  | 
|
Operating humidity range (storage temperature range)  | 
5°C to 45°C (-10°C to +60°C)  | 
|
operating system  | 
Windows 7, 32-bit or above  | 



      
        Copyright © 2025 by Shenzhen Sonka Medical Technology Co., Limited - Privacy policy