| Project name | Parameter | Specification | 
| Machine parameters | Data output interface | LAN network port*1 USB*2 | 
| Power supply | 100V~240V,50/60Hz | |
| Power rating | (100W)Maximum | |
| LCD screen | 21.5inch | |
| ID card reader | ||
| Operating humidity range (storage temperature range) | 5℃~45℃(-10℃~+60℃) | |
| Operating System | Windows 10 (More than 32) | |
| Data Transmission Mode | internet access、WIFI | |
| Overall Dimension | 1800(length)*1200( Width)*2450(height )mm | |
| Weight | About 220KG | |
| Height | Measuring system | Ultrasonic measurement (high precision temperature difference compensation) | 
| Measuring range | 70.0~205cm | |
| Permissible error | ±0.5cm | |
| Weight | Measuring system | Precision balance beam pressure sensor weighing | 
| BMI | The automatic intelligence calculates the body mass index | |
| Measuring range | 1~300kg | |
| Permissible error | ±0.1kg | |
| Body fat | Measuring frequency | Multi frequency 4- electrode | 
| Electrode material | Electroplating material | |
| Measuring range | 200~1000Ω | |
| Body temperature (DT-8836) | Display exact number | 0.1 ℃ | 
| Human body temperature measurement | 32.0~42.5℃ | |
| Object temperature measurement | 0~100℃ | |
| Accuracy | ≤±0.3℃ | |
| Power Consumption | ≤120mw | |
| Measuring distance | 5-8cm | |
| Auto Power -Off | About 15 second | |
| Blood pressure(RBP-7000) | Display | Digital display | 
| Measuring method | Oscillographic method | |
| Measuring range | Pressure (0~300) mmHg [ (0~ 40)kPa] rate 30/minute~200/minute | |
| Accuracy | Pressure 士2mmHg(士0.267kPa)within Rate士2% within | |
| Screen | LCD screen | |
| Data Transmission Mode | 232 port/USB | |
| Power Supply | Power Adapter(Input AC100V~240V,50/60Hz,Output DC12V,3.5A) | |
| Operating temperature and humidity | 5℃~40℃,15%RH~80%RH | |
| Transport and storage temperature and humidity | -20℃~+55℃,≤93%RH | |
| Operating atmospheric pressure | 80kPa~106kPa | |
| Transport and storage atmospheric pressure | 50kPa~106kPa | |
| Overall dimensions | 387.7mm(L)×244.1mm(W)×340.2mm(H) | |
| Net Weight | About 6.0Kg | |
| Cuff applies to perimeter range | 17cm~42cm | |
| Blood oxygen KS-CM01 | Sensor | Dual wavelength light emitting diode | 
| Wavelength | Red Lights:663nm | |
| Infrared light:890nm | ||
| Measuring range | 35%~100%; | |
| Maximum average optical Output power | ≤2mW | |
| Permissible error | The measurement error was ±2% in the range of 70% to 100% | |
| Pulse rate measurement error | Tolerance of 30-250bpm was ±2bpm or ±%2, which was the maximum | |
| Single lead ECG | Operating temperature | 5℃~40℃ | 
| Environment temperature | 30%~80% Non - Condensing | |
| Range of atmospheric Pressure | 70KPa~106KPa | |
| Heart rate measurement range | 30bpm~240bpm | |
| Accuracy of heart rate Measurement | The maximum value is ± 2BPM or ±2 | |
| Waveform display sensitivity | 5.0mm/mv error±10% | |
| Scanning speed | 20mm/s error±10% | |
| Input impedance | ≥5.0Ω | |
| Operating voltage | d.c.2.5V±0.2V | |
| Blood sugar, uric acid, total cholesterol (BeneCheck BKM13-1) | Specimens | Whole fingertip micro-vascular blood | 
| Detection time | Blood sugar 10 seconds; uric acid 15 seconds; total cholesterol 26 seconds | |
| Measuring range | blood glucose:20-600mg/dL (1.1-33.3mmol/L) Uric Acid:3-20mg/dL(0.18-1.19mmol/L) Total cholesterol:100-400mg/dL(2.59-10.35mmol/L) | |
| Liquid volume inspector | blood glucose 0.9uL,Total cholestero l10uL, Uric Acid 1uL | |
| Storage Temperature | 10℃-30℃ | |
| Operating Temperature | 10℃-40℃ | |
| Relative humidity | <95% | |
| Memory capacity | Blood glucose 360 group, total cholesterol 50 group, uric acid 50 group | |
| Battery type | A 3V (CR2032) button lithium battery | |
| Validity of battery | About 1000 tests | |
| Camera | Pixels | 5 million | 
| Port | USB 2.0 | |
| Driver | free drive | |
|  Thermal printer(SP-EU58) | Printing method | Line thermal printing | 
| Printing paper | (straight roll) Heat sensitive 57.5mm× paper roll 100mm (MAX) | |
| Carriage Paper Width | 57.5±0.5 mm | |
| Effective print width | 48mm | |
| Image resolution | 8 /mm(203dp) | |
| Printing speed | Max 80mm/S(No more than 25% print points per line) | |
| Paper thickness | 0.06~0.08 mm | |
| Print head span | 50KM | |
| Operating ambient temperature/humidity | 0-50℃/10-80% | |
| Temperature/humidity of the storage environment | -20-60℃/10-90% | 


 
       